
CONFIGURATION
Industrial router IPL-E User guide ref. 9015909-03 Page 91
Product start-up :
If that option is selected, the router will send an SNMP trap each time it will
connect to the Internet
20.2.2 Digital output alarm
If an alarm occurs, the router will open the digital output..
The causes which make the output to open cane be either the
ADSL disconnection, power input 1 failure, power input 2 failure.
20.2.3 E-mail alarm
When the digital input is closed or opened, an email can be transmitted to
one of the users of the users list.
To set that function select the “Alarm” menu and click “email”.
Enable the alarm email
:
Select this option if you want an email to be sent to a user when the digital input 1 is set
ON or OFF.
Alarm launched on event
:
If the option OPEN is selected, the alarm will be sent each time the digital
input will be opened.
If the option CLOSED is selected, the alarm will be sent each time the
digital input will be opened.
If the option BOTH is selected, the alarm will be sent each time the digital
input will be opened or closed.
Hold time :
Select the time the input has to stay in its alarm state to be taken into account.
Alarm destination
:
Select the user to whom the email must be sent.
Text to send
:
Enter the email text.
Comentários a estes Manuais