CONFIGURATION
Page 66 User guide ref. 9015909-03 Industrial router IPL-E
16.2 Configuring a M2Me_Connect connection
Step 1 : Router configuration
• Select the « Setup» menu, the « Remote users » menu, the
“M2Me_Connect” menu, and then the “Connection” menu.
« Activate » parameter:
Tick the checkbox
“TCP ports” and “UDP ports” parameters :
Select the ports the router must check to set a connection to the
M2Me_Connect service.
Proxy parameters :
If a proxy server is in charge of filtering IP packets transmitted towards the
Internet,
select the “Use a Proxy server” option;
choose either “HTTP” or “SOCK S5”;
Enter the Proxy server address, port number, Login and password.
•
••
•
Test the connection
Click the “Control” menu, and press the “connect now” button.
Go to the ”Diagnostic” menu, “Network status” menu and then “M2Me”.
When the connection between the router and the M2Me_Connect service
is established, the port number and protocol are displayed.
•
••
•
Deselect the ports number needlessly selected
If too many ports have been selected, the connection delay may be long; it
is why we advise to unselect all the ports except the one which has finally
been successful.