INSTALLATION
Industrial router IPL-E User guide ref. 9015909-03
Page 19
1.3 DIP-switches & push-button
DIP switches
SW 1 SW 2
Management
OFF OFF
The current IP@ of the product is the stored IP @
ON OFF
The active IP@ of the product is the factory IP@ : 192.168.0.128
No login and password are required to access to the html server.
OFF ON
The active IP@ is provided by the BOOTP or DHCP server.
ON ON
Reserved
Push-button : It enables to restore the factory profile.
To restore the factory profile, switch the power on while pressing the push-
button until the RUN light turns green.
Attention : Once the factory profile has been restored, the stored
configuration is lost.
2 Ventilation
To avoid overheating when the ambient temperature is high, leave a 1 cm
(0.5 inch) space on each side of the product.
3 Supply voltage
The supply voltage must be strictly lower than 30 VDC and higher than 10
VDC. The consumption is 170 mA at 24 VDC.
4 Ethernet ports
The IPL-E features auto-sensing 10/100 Mbps MDI/MDI-X LAN ports.
The upper RJ45 Ethernet connector is the interface on which safe VPN
links can be set. It is named the WAN interface.