CONFIGURATION
Page 88 User guide ref. 9015909-03 Industrial router IPL-E
• Select the “transparent” and then the “raw server COM1” or the “raw
server COM2” menu.
• Enable the raw server gateway and set up the parameters as follows :
“RS232/485 input buffer size” parameter :
Set up the maximum length of an asynchronous string the gateway will
store before transmitting it to the IP network.
“Timeout of RS232/485 end of frame” parameter :
Set up the delay the gateway will wait before declaring complete a string
received from the asynchronous device.
Once declared complete, the gateway will transmit the string to the IP
network.
“TCP inactivity Timeout” parameter :
Set up the time the gateway will wait before disconnecting the TCP link if
no characters are detected.
“TCP port number” parameters :
Set up the port number the gateway has to use.
If the Raw TCP server gateway is assigned to both serial COM ports, the
TCP port numbers must be different on each port.
19.3 RAW UDP gateway
19.3.1 Overview
The RAW UDP gateway enables you to connect together a group of serial
or IP devices through an IP network.
The group can include IP devices if they have the software pieces able to
receive or transmit serial data inside UDP.
Serial data transmitted by each device is transmitted to all other serial
devices through the IP network.
A table of IP destination gateways is stored in each IPL-E belonging to the
group.
The serial data is encapsulated in the UDP protocol.
The UDP frame is sent to each destination IP address stored in the table.