DIP-SWITCHES SET UP
1 Overview
The XSLAN can be configured either with DIP switches or with an html
browser through Ethernet.
The DIP switch configuration is very simple; it will be preferred when the
distance is under the limit of the product and when only simple functions
are required.
The Html server set up is mandatory
when the distance between two SHDSL switches is close to the limit
to take advantage of the Diagnostic functions,
or when advanced functions like VLAN, Quality of Service, serial
gateways, which can only be configured with the html server, are
required.
2 One twisted pair SHDSL line setup
When two XSLAN SHDSL switches a
connected through a 1 twisted pair line,
the port of the first one has to be set as
an LTU (calling party) and the port of
the other one has to be configur
an NTU (called party).
re
ed as
The SHDSL switch port which is named LTU negotiates and forces the
data rate over the line; the NTU can only accept.
The data rate can be either negotiated by the LTU itself (auto mode) , or
imposed by the user with the DIP switches.
Switch Shdsl XSLAN Notice d’utilisation ref 9014309-01
page 21