XSLAN SHDSL switch _________________ User’s guide Document reference : 9014709-02 _________________ www.hvssystem.comSiège social :2 rue
INSTALLATION 1 Product description 10 / 100 BT12SHDSL134110 / 100 BT12RS485RS232Rx TxSHDSL1110 / 100 BT12RS232SHDSL12RS2321 XSLAN-1400 XSLA
INSTALLATION 1.1 Leds 10 / 100 BT12RS232SHDSL12RS485Not usedOPERATION ledEthernet activity ledport 1 & port 2SHDSL Errorsport 1 & port 2RX
INSTALLATION XSLAN SHDSL switch User’s guide ref 9014709-02 Page 13 1.2 Connectors 8 pins screw block Supply voltage and input / output Pin Nr
INSTALLATION Page 14 User’s guide ref 9014709-02 XSLAN SHDSL switch RS485 2 pins screw block Pin Nr Signal Function 1 A RS485 polarity A 2
INSTALLATION XSLAN SHDSL switch User’s guide ref 9014709-02 Page 15 1.3 DIP switches and push-button DIP switches SW 1 SW 2 Management OFF OF
INSTALLATION Page 16 User’s guide ref 9014709-02 XSLAN SHDSL switch 2 Ventilation To avoid overheating when the ambient temperature is high,
INSTALLATION 6 RS232 (XSLAN—1220, 1230, 2220 and -2230) The RS232 data rate can be tuned from 1200 to 115200 b/s with parity (even / odd) or no par
INSTALLATION 8 SHDSL line Remark : For test purpose on a desk, the line can be replaced by any Ethernet straight cable. Connecting the XSLAN to t
INSTALLATION We have selected the Phoenix Contact module TT-2-PE-24D; it must be wired as indicated opposite. Line cable shield : If the line is s
The XSLAN SHDSL switch is manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL : + 33 4-76-04-20-00 FAX : + 33
INSTALLATION 9 Input and output Input That input is not isolated. if it is opened, an SNMP trap will be sent to the SNMP server is that function
DIP-SWITCHES SET UP 1 Overview The XSLAN can be configured either with DIP switches or with an html browser through Ethernet. The DIP switch confi
DIP SWITCHES SET UP Page 22 User’s guide ref 9014709-02 XSLAN SHDSL switch • XSLAN Nr 1 setup Setup the XSLAN Nr 1 as a LTU and set the data
DIP-SWITCHES SET UP 3 Two twisted pairs SHDSL line set up (XSLAN-2400, 2220, 2230) When two XSLANs SHDSL switches are connected through a 2 twisted
DIP SWITCHES SET UP Page 24 User’s guide ref 9014709-02 XSLAN SHDSL switch 4 Testing the SHDSL connection and adjusting the data rate • Conn
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 25 Setting-up the XSLAN with the Html server is mandatory w
HTML SET UP & DIAGNOSTIC Page 26 User’s guide ref 9014709-02 XSLAN SHDSL switch 2 Enabling html configuration Coming from factory, the DIP
HTML SET UP & DIAGNOSTIC Copy and paste : Parameters must be entered with the keyboard; they cannot be pasted. However, it can be useful to paste
HTML SET UP & DIAGNOSTIC Page 28 User’s guide ref 9014709-02 XSLAN SHDSL switch 3.3 Modifying the configuration from the LAN Step 1 : Ensur
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 29 Remark : The SW01 and SW02 must not be left in that position
CONTENT XSLAN SHDSL switch User’s guide ref 9014709-02 Page 3 OVERVIEW 1 PRODUCTS IDENTIFICATION...
HTML SET UP & DIAGNOSTIC 9 Assigning an IP address to the LAN interface An IP address must be assigned to that interface. The HTML server is
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 31 A route is a table which registers which gateway address must
HTML SET UP & DIAGNOSTIC To register a route, • select the “IP protocol & routing” menu and then the “routing” menu, • click the ”Add a r
HTML SET UP & DIAGNOSTIC 11 One twisted pair SHDSL connection set up 11.1 Set up When two XSLAN SHDSL switches aconnected through a line, the
HTML SET UP & DIAGNOSTIC Page 34 User’s guide ref 9014709-02 XSLAN SHDSL switch 11.2 Testing the SHDSL connection and adjusting the data rat
HTML SET UP & DIAGNOSTIC 12 Two twisted pairs SHDSL connection set up When two XSLANs SHDSL switches are connected through a 2 twisted pairs li
HTML SET UP & DIAGNOSTIC Page 36 User’s guide ref 9014709-02 XSLAN SHDSL switch Setting up The XSLAN Nr 2 • Select the Ethernet & switch
HTML SET UP & DIAGNOSTIC 13 VLAN set up 13.1 Overview VLAN is a flexible group of devices that can be located anywhere in a network, but than
HTML SET UP & DIAGNOSTIC Page 38 User’s guide ref 9014709-02 XSLAN SHDSL switch Before being transmitted to the port the Ethernet frames are
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 39 13.2 VLAN set up • Select the “Ethernet” menu and then the
CONTENT Page 4 User’s guide ref 9014709-02 XSLAN SHDSL switch DIP SWITCHES CONFIGURATION 1 OVERVIEW...
HTML SET UP & DIAGNOSTIC Page 40 User’s guide ref 9014709-02 XSLAN SHDSL switch 14 Quality of service (QoS) set up 14.1 DiffServ benefits
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 41 • Assigning each traffic to the classes Each traffic (Serv
HTML SET UP & DIAGNOSTIC Step 5 : Classify the traffics • Select the QoS menu and then the “Traffic classification” menu. • Click the “Add a
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 43 15 SNMP set up The XSLAN is compliant with the MIB2. The S
HTML SET UP & DIAGNOSTIC Page 44 User’s guide ref 9014709-02 XSLAN SHDSL switch 16 Serial gateway set up The XSLAN-1220 or 2220 features 1
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 45 16.1 Modbus gateway The ETIC modbus gateway is made to link m
HTML SET UP & DIAGNOSTIC To configure the Modbus server gateway, • select the modbus menu and then modbus server, • enable the modbus serve
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 47 received character of a modbus answer frame on the serial inte
HTML SET UP & DIAGNOSTIC 16.1.2 “Modbus client” gateway That gateway can be used only if a serial modbus master device is connected to the seri
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 49 “TCP inactivity Timeout” parameter : Set the time the gateway
CONTENT XSLAN SHDSL switch User’s guide ref 9014709-02 Page 5 … HTML CONFIGURATION 13 VLAN SET UP...
HTML SET UP & DIAGNOSTIC 16.2 RAW TCP gateway 16.2.1 Raw client gateway The RAW client gateway can be used if a serial “master” device has t
HTML SET UP & DIAGNOSTIC “TCP port number” parameter : Set the port number the gateway has to use. If the Raw TCP client gateway is assigned t
HTML SET UP & DIAGNOSTIC Page 52 User’s guide ref 9014709-02 XSLAN SHDSL switch string to the IP Once declared complete, the gateway will tr
HTML SET UP & DIAGNOSTIC 16.3 RAW UDP gateway 16.3.1 Overview The RAW UDP gateway enables you to connect together a group of serial or IP dev
HTML SET UP & DIAGNOSTIC Page 54 User’s guide ref 9014709-02 XSLAN SHDSL switch • Select the “Activate” option. « Serial input buffer size”
HTML SET UP & DIAGNOSTIC 16.4 Multicast gateway Internet Protocol multicast is a bandwidth-conserving technology that reduces traffic by simul
HTML SET UP & DIAGNOSTIC Page 56 User’s guide ref 9014709-02 XSLAN SHDSL switch The Internet Assigned Numbers Authority (IANA) controls the
HTML SET UP & DIAGNOSTIC XSLAN SHDSL switch User’s guide ref 9014709-02 Page 57 16.5 Unitelway gateway The unitelway gateway is made to conne
HTML SET UP & DIAGNOSTIC Page 58 User’s guide ref 9014709-02 XSLAN SHDSL switch 17 Diagnostic menu • Logs : The log displays the last 300
APPENDIX DATA RATE VERSUS DISTANCE XSLAN SHDSL switch User’s guide ref 9014709-02 Page 59 Maximum distance between 2 switches versus data r
INSTALLATION Switch Shdsl XSLAN Notice d’utilisation ref 9014309-01 page 6 1 Products identification XSLAN SHDSL switch 1400 1220 1230 2400 2
APPENDIX 2 HTML server XSLAN SHDSL switch User’s guide ref 9014709-02 Page 61 System Administration To protect access to the administration ser
APPENDIX 2 HTML server Page 62 User’s guide ref 9014709-02 XSLAN SHDSL switch Alarms To set the alarms SNMP To define traps and SNMP server
APPENDIX 2 HTML server XSLAN SHDSL switch User’s guide ref 9014709-02 Page 63
13, Chemin du Vieux Chêne 38240 Meylan France Tel : 33 4 76 04 20 00 Fax : 33 4 76 04 20 01 E-mail : contact@eticte
INSTALLATION 2 Product overview 2.1 Function The XSLAN shdsl switch enables to extend an Ethernet network over kilometers using one or two simple
INSTALLATION Page 8 User’s guide ref 9014709-02 XSLAN SHDSL switch 2.3 Ethernet ports The XSLAN provides 2 or 4 Ethernet RJ45 interfaces (depe
INSTALLATION XSLAN SHDSL switch User’s guide ref 9014709-02 Page 9 3 Data-sheet Dimensions 137 x 48 x 116 mm (h, l, d) C.E.M EN50082-2 Electri